ZHCSLG4B July   2020  – May 2022 TLIN1027-Q1

PRODUCTION DATA  

  1. 特性
  2. 应用
  3. 说明
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 ESD Ratings - IEC
    4. 6.4 Thermal Information
    5. 6.5 Recommended Operating Conditions
    6. 6.6 Electrical Characteristics
    7. 6.7 Switching Characteristics
    8. 6.8 Timing Requirements
    9. 6.9 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1  LIN (Local Interconnect Network) Bus
        1. 8.3.1.1 LIN Transmitter Characteristics
        2. 8.3.1.2 LIN Receiver Characteristics
          1. 8.3.1.2.1 Termination
      2. 8.3.2  TXD (Transmit Input and Output)
      3. 8.3.3  RXD (Receive Output)
      4. 8.3.4  VSUP (Supply Voltage)
      5. 8.3.5  GND (Ground)
      6. 8.3.6  EN (Enable Input)
      7. 8.3.7  Protection Features
      8. 8.3.8  Bus Stuck Dominant System Fault: False Wake-Up Lockout
      9. 8.3.9  Thermal Shutdown
      10. 8.3.10 Under Voltage on VSUP
      11. 8.3.11 Unpowered Device and LIN Bus
    4. 8.4 Device Functional Modes
      1. 8.4.1 Normal Mode
      2. 8.4.2 Sleep Mode
      3. 8.4.3 Standby Mode
      4. 8.4.4 Wake-Up Events
        1. 8.4.4.1 Wake-Up Request (RXD)
        2. 8.4.4.2 Mode Transitions
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedures
        1. 9.2.2.1 Normal Mode Application Note
        2. 9.2.2.2 Standby Mode Application Note
      3. 9.2.3 Application Curves
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 Receiving Notification of Documentation Updates
    3. 12.3 支持资源
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 术语表
  13. 13Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Normal Mode

If the EN pin is high at power up the device will power up in normal mode. If the EN pin is low, it will power up in standby mode. The EN pin controls the mode of the device. In normal operational mode the receiver and transmitter are active and the LIN transmission up to the LIN specified maximum of 20 kbps is supported. The receiver detects the data stream on the LIN bus and outputs it on RXD for the LIN controller. A recessive signal on the LIN bus is a logic high and a dominant signal on the LIN bus is a logic low. The driver transmits input data from TXD to the LIN bus. Normal mode is entered as EN transitions high while the TLIN1027-Q1 is in sleep or standby mode for > tMODE_CHANGE plus tNOMINT.