ZHCSQ68A May 2022 – December 2022 TLIN1431-Q1
PRODUCTION DATA
There is an internal pull-up resistor with a serial diode structure to VSUP, so no external pull-up components are required for the LIN responder node applications. An external pull-up resistor (1 kΩ) and a series diode to VSUP must be added when the device is used for commander node applications as per the LIN specification (ISO 17987-4).
Figure 8-3 shows a Commander Node configuration and how the voltage levels are defined.