ZHCSHH1B January 2018 – November 2019 TLV6700
PRODUCTION DATA.
To ensure proper voltage levels, the pullup resistor value is selected by ensuring that the pullup voltage divided by the resistor does not exceed the sink-current capability of the device. This confirmation is calculated by verifying that the pullup voltage minus the output-leakage current (Ilkg(OD)) multiplied by the resistor is greater the desired logic-high voltage. These values are specified in the Electrical Characteristics table.
Use Equation 6 to calculate the value of the pullup resistor.