over operating junction temperature range (unless otherwise noted) | MIN | MAX | UNIT |
---|
Voltage | VDD(2) | 0 | 6.5 | V |
All other pins(2) | –0.3 | +6.5 |
Current | Maximum low output current, IOL | | 5 | mA |
Maximum high output current, IOH | | –5 |
Input clamp current, IIK (VI < 0 or VI > VDD) | | ±20 |
Output clamp current, IOK (VO < 0 or VO > VDD) | | ±20 |
Temperature | Operating junction temperature range, TJ | –40 | 125 | °C |
Storage temperature range, Tstg | –65 | 150 |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to GND. For reliable operation the device
should not be operated at 6.5 V for more than t = 1000h continuously