ZHCSGB8C May 2017 – October 2019 TMP464
PRODUCTION DATA.
The local and remote temperature sensors have a resolution of 13 bits (0.0625°C). Temperature data that result from conversions within the default measurement range are represented in binary form, as shown in the Standard Binary column of Table 1. Negative numbers are represented in two's-complement format. The resolution of the temperature registers extends to 255.9375°C and down to –256°C, but the actual device is limited to ranges as specified in the Electrical Characteristics table to meet the accuracy specifications. The TMP464 device is specified for ambient temperatures ranging from –40°C to +125°C; parameters in the Absolute Maximum Ratings table must be observed to prevent damage to the device.
TEMPERATURE
(°C) |
LOCAL OR REMOTE TEMPERATURE REGISTER VALUE
(0.0625°C RESOLUTION) |
|
---|---|---|
STANDARD BINARY(1) | ||
BINARY | HEX | |
–64 | 1110 0000 0000 0000 | E0 00 |
–50 | 1110 0111 0000 0000 | E7 00 |
–25 | 1111 0011 1000 0000 | F3 80 |
–0.1250 | 1111 1111 1111 0000 | FF F0 |
–0.0625 | 1111 1111 1111 1000 | FF F8 |
0 | 0000 0000 0000 0000 | 00 00 |
0.0625 | 0000 0000 0000 1000 | 00 08 |
0.1250 | 0000 0000 0001 0000 | 00 10 |
0.1875 | 0000 0000 0001 1000 | 00 18 |
0.2500 | 0000 0000 0010 0000 | 00 20 |
0.3125 | 0000 0000 0010 1000 | 00 28 |
0.3750 | 0000 0000 0011 0000 | 00 30 |
0.4375 | 0000 0000 0011 1000 | 00 38 |
0.5000 | 0000 0000 0100 0000 | 00 40 |
0.5625 | 0000 0000 0100 1000 | 00 48 |
0.6250 | 0000 0000 0101 0000 | 00 50 |
0.6875 | 0000 0000 0101 1000 | 00 58 |
0.7500 | 0000 0000 0110 0000 | 00 60 |
0.8125 | 0000 0000 0110 1000 | 00 68 |
0.8750 | 0000 0000 0111 0000 | 00 70 |
0.9375 | 0000 0000 0111 1000 | 00 78 |
1 | 0000 0000 1000 0000 | 00 80 |
5 | 0000 0010 1000 0000 | 02 80 |
10 | 0000 0101 0000 0000 | 05 00 |
25 | 0000 1100 1000 0000 | 0C 80 |
50 | 0001 1001 0000 0000 | 19 00 |
75 | 0010 0101 1000 0000 | 25 80 |
100 | 0011 0010 0000 0000 | 32 00 |
125 | 0011 1110 1000 0000 | 3E 80 |
127 | 0011 1111 1000 0000 | 3F 80 |
150 | 0100 1011 0000 0000 | 4B 00 |
175 | 0101 0111 1000 0000 | 57 80 |
191 | 0101 1111 1000 0000 | 5F 80 |
Both local and remote temperature data use two bytes for data storage with a two's-complement format for negative numbers. The high byte stores the temperature with 2°C resolution. The second or low byte stores the decimal fraction value of the temperature and allows a higher measurement resolution, as shown in Table 1. The measurement resolution for both the local and the remote channels is 0.0625°C.