ZHCSA18F March 2009 – February 2021 TMS320C28341 , TMS320C28342 , TMS320C28343 , TMS320C28343-Q1 , TMS320C28344 , TMS320C28345 , TMS320C28346 , TMS320C28346-Q1
PRODUCTION DATA
MODE | TEST CONDITIONS | IDD | IDDIO (2) | IDD18 | ||||||
---|---|---|---|---|---|---|---|---|---|---|
25°C | 105°C | 125°C | 25°C | 105°C | 125°C | 25°C | 105°C | 125°C | ||
Typical operation | The following peripheral clocks are enabled:
| 200 mA | 380 mA | 500 mA | 45 mA | 45 mA | 45 mA | 45 mA | 43 mA | 40 mA |
IDLE | Peripheral clocks are off. XCLKOUT is turned off. | 95 mA | 275 mA | 395 mA | 15 mA | 15 mA | 18 mA | 45 mA | 43 mA | 40 mA |
STANDBY | Peripheral clocks are off. | 45 mA | 225 mA | 345 mA | 15 mA | 15 mA | 18 mA | 45 mA | 43 mA | 40 mA |
HALT | Peripheral clocks are off. Input clock is disabled.(4) | 40 mA | 220 mA | 340 mA | 15 mA | 15 mA | 18 mA | 550 μA | 550 μA | 550 μA |
The IDD numbers in Section 7.5.2 are valid for the TMS320C28345 and TMS320C28343 devices only. For the TMS320C28341 device, subtract the IDD current numbers for those peripherals that do not exist on this device (see Table 7-1) from the IDD current numbers shown in Section 7.5.2.