ZHCSV76A June 2022 – March 2024 TMS570LC4357-SEP
PRODUCTION DATA
请参考 PDF 数据表获取器件具体的封装图。
These 3 trip zone inputs are driven by external circuits and are connected to device-level inputs. These signals are either connected asynchronously to the ePWMx trip zone inputs, or double-synchronized with VCLK3, or double-synchronized and then filtered with a 6-cycle VCLK3-based counter before connecting to the ePWMx (see Figure 8-2). By default, the trip zone inputs are asynchronously connected to the ePWMx modules.
TRIP ZONE INPUT | CONTROL FOR ASYNCHRONOUS CONNECTION TO ePWMx | CONTROL FOR DOUBLE-SYNCHRONIZED CONNECTION TO ePWMx | CONTROL FOR DOUBLE-SYNCHRONIZED AND FILTERED CONNECTION TO ePWMx(1) |
---|---|---|---|
TZ1n | PINMMR172[18:16] = 001 | PINMMR172[18:16] = 010 | PINMMR172[18:16] = 100 |
TZ2n | PINMMR172[26:24] = 001 | PINMMR172[26:24] = 010 | PINMMR172[26:24] = 100 |
TZ3n | PINMMR173[2:0] = 001 | PINMMR173[2:0] = 010 | PINMMR173[2:0] = 100 |