ZHCSMX0B September 2019 – December 2020 TPA6304-Q1
PRODUCTION DATA
The shorted load (SL) test triggers a fault condition if the conductive path between the OUT_(i)M pin and OUT_(i)P pin of the tested channel (i) has an impedance below the threshold set in DC Load Diagnostics Control Register 4 and DC Load Diagnostics Control Register 5. The SL test has a configurable threshold depending on the expected load to be connected. Because the speakers and cable impedance connected to each channel might be different, each channel can be assigned a unique threshold value.
The open load (OL) test triggers a fault condition if the conductive path between the OUT_(i)M pin and OUT_(i)P pin of the tested channel (i) has an impedance higher than that specified in the Specifications section.