ZHCSAL0D March 2016 – August 2020 TPD3S716-Q1
PRODUCTION DATA
The TPD3S716-Q1 operates in normal operation modes when enabled, both VBUS_SYS and VIN are above their UVLO thresholds, and the device is not in any fault conditions. Table 8-1 shows the normal operating modes of the TPD3S716-Q1.
MODE | VEN | DEN | VBUS PATH | DATA PATH |
---|---|---|---|---|
USB Host | 0 | 0 | ON | ON |
Power Only | 0 | 1 | ON | OFF |
USB Client/OTG | 1 | 0 | OFF | ON |
Disabled | 1 | 1 | OFF | OFF |