ZHCSP75A July 2022 – December 2022 TPS1HC30-Q1
PRODUCTION DATA
Table 8-1 is when DIAG_EN is enabled. When DIAG_EN is low, current sense and FLT are disabled. The output is in high-impedance mode. For details, refer to the following table.
DIAG_EN | IN Condition | Protections and Diagnostics |
---|---|---|
HIGH | ON | See Fault Table |
OFF | ||
LOW | ON | Diagnostics disabled, protection normal SNS and FLT are high impedance |
OFF |
Conditions |
EN |
VOUT |
Latch |
FLT |
SNS |
Behavior | Recovery |
---|---|---|---|---|---|---|---|
Normal |
L |
L |
x |
Hi-Z |
0 | Normal | |
H |
ILOAD × RON |
x |
Hi-Z |
ILoad / Ksns | Normal | ||
Overcurrent |
H |
VBB – ILIM × RLOAD |
x |
L |
VSNSFH | Holds the current at the current limit until thermal shutdown or when the overcurrent event is removed | |
STG, Relative Thermal Shutdown, Absolute Thermal Shutdown |
H |
H/L |
L |
L |
VSNSFH | Shuts down when devices hits relative or absolute thermal shutdown | Auto retries when THYSis met and it has been longer than tRETRY amount of time |
H |
H/L |
H |
L |
VSNSFH | Shuts down when devices hits relative or absolute thermal shutdown | Stays off until latch or enable is toggled | |
Open load, STB |
H |
H |
x |
Hi-Z |
ILoad / KSNS = ~0 | Normal behavior, user can judge through the SNS pin output if it is an open load or not | |
L |
H |
x |
L |
VSNSFH | Internal pullup resistor is active. If VBB – VOUT < VOL then fault active. | Clears when fault goes away | |
Reverse Polarity |
x |
x |
x |
x |
x | Channel turns on to lower power dissipation. Current into ground pin is limited by external ground network. |
Fault Condition |
Deglitch Time |
---|---|
ILIM |
2.5 µs |
TREL |
2.5 µs |
TABS |
20 µs |
Open Load |
500 µs |