ZHCSIQ0F August 2018 – August 2020 TPS2120 , TPS2121
PRODUCTION DATA
After input settling and soft start time, the TPS2121 utilizes a fast switchover to minimize output voltage drop. Where VSW is the output voltage when the switchover is triggered and tSW is the time until the output voltage stops dipping. The amount of voltage dip during the switchover time is a function of output load current (IOUT) and load capacitance (COUT). The minimum output voltage during switchover can be found using the following equations:
Where:
If switching from a lower to a higher voltage, the selected channel will not detect reverse voltage and shall turn on immediately using the current monitor to limit the output current to a safe level. If the output current reaches the current limit during fast switchover, this will increase the total time until the output reaches steady state.
If an input is selected while the output voltage is still a higher voltage, that channel will continue to block reverse current by waiting to fast turn on until the output drops below the VRCB threshold.