The TPS23751 and TPS23752 provide a fixed internal compensation ramp that suffices for most applications. RS (see Figure 32) may be used if the internally provided slope compensation is not enough. Most current-mode control papers and application notes define the slope values in terms of VPP/TS (peak ramp voltage / switching period). Assuming that the desired slope, VSLOPE_D (in mV/period), as shown in Figure 1, is based on the full period, compute RS per the following equation where VPK and ICS_RAMP are from the electrical characteristics table with voltages in mV and current in μA.
CS may be required if the presence of RS causes increased noise, due to adjacent signals like the gate drive, to appear at the CS pin.