The fault timer runs when the hot swap is in power limit or current limit, which is the case during start-up. Thus the timer has to be sized large enough to prevent a time-out during start-up. If the part starts directly into current limit (ILIM x VDS < PLIM) the maximum start time can be computed with Equation 17:
For most designs (including this example) ILIM x VDS > PLIM so the hot swap will start in power limit and transition into current limit. In that case the start time can be computed as follows:
The actual startup time is slightly longer, as the power limit is a function of VDS and decreases as the output voltage increases. To ensure that the timer never times out during start-up, TI recommends to set the fault time (tflt) to be 1.75 x tstart or 5.11ms. This accounts for the variation in power limit, timer current, and timer capacitance. Thus CTIMER can be computed as follows:
The next largest available CTIMER is chosen as 33 nF. Once the CTIMER is chosen the actual programmed fault time can be computed as follows: