ZHCSTM4A October 2023 – March 2024 TPS25751
PRODUCTION DATA
PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
---|---|---|---|---|---|---|
VOVP4RCP | VBUS overvoltage protection for RCP programmable range | OVP detected when VVBUS > VOVP4RCP | 5.0 | 24 | V | |
VOVP4RCPH | Hysteresis | 1.75 | 2 | 2.25 | % | |
rOVP | Ratio of OVP4RCP input used for OVP4VSYS comparator. rOVP × VOVP4VSYS = VOVP4RCP | setting 0 | 1 | V/V | ||
setting 1 | 0.95 | V/V | ||||
setting 2 | 0.90 | V/V | ||||
setting 3 | 0.875 | V/V | ||||
VOVP4VSYS | VBUS overvoltage protection range for VSYS protection | OVP detected when rOVP × VVBUS > VOVP4RCP | 5 | 27.5 | V | |
VOVP4VSYS | Hysteresis | VBUS falling, % of VOVP4VSYS, rOVP setting 0 | 1.75 | 2 | 2.25 | % |
VBUS falling, % of VOVP4VSYS, rOVP setting 1 | 1.8 | 2.1 | 2.4 | |||
VBUS falling, % of VOVP4VSYS, rOVP setting 2 | 1.9 | 2.2 | 2.5 | |||
VBUS falling, % of VOVP4VSYS, rOVP setting 3 | 2 | 2.3 | 2.6 | |||
VPP5V_UVLO | Voltage required on PP5V | rising | 3.9 | 4.1 | 4.3 | V |
falling | 3.8 | 4.0 | 4.2 | |||
hysteresis | 0.1 | |||||
IDSCH | VBUS discharge current | VVBUS = 22 V, measure IVBUS | 4 | 15 | mA |