ZHCSOF7B september 2022 – june 2023 TPS25990
PRODUCTION DATA
OC_TIMER is a manufacturer-specific register used to program the overcurrent blanking digital timer duration as described in Section 8.3.4.2.
This command uses the PMBus® read/write byte protocol.
The details of this register are shown in Table 9-69.
Bit | Name | Description | Value | Overcurrent Blanking Timer Duration (ms) | Default Value | Access |
---|---|---|---|---|---|---|
7:0 | OC_TIMER | Overcurrent blanking digital timer | 0x00h | 0 | 0x14h | Read/Write |
0x01h | 0.109 | |||||
0x02h | 0.218 | |||||
0x03h | 0.327 | |||||
0x04h | 0.436 | |||||
0x05h | 0.545 | |||||
0x06h | 0.654 | |||||
0x07h | 0.763 | |||||
... | ||||||
0x0Ah | 1.09 | |||||
... | ||||||
0x14h | 2.18 | |||||
... | ||||||
0x64h | 10.9 | |||||
... | ||||||
0xC8h | 21.8 | |||||
... | ||||||
0xFFh | 27.8 |
A write command to this register should be preceded by the MFR_WRITE_PROTECT command to unlock the device first to prevent accidental accidental/spurious writes.