ZHCSOF7B september   2022  – june 2023 TPS25990

PRODUCTION DATA  

  1.   1
  2. 特性
  3. 应用
  4. 说明
  5. Revision History
  6. 说明(续)
  7. Pin Configuration and Functions
  8. Specifications
    1. 7.1  Absolute Maximum Ratings
    2. 7.2  ESD Ratings
    3. 7.3  Recommended Operating Conditions
    4. 7.4  Thermal Information
    5. 7.5  Electrical Characteristics
    6. 7.6  Logic Interface DC Characteristics
    7. 7.7  Telemetry
    8. 7.8  PMBus Interface Timing Characteristics
    9. 7.9  External EEPROM Interface Timing Characteristics
    10. 7.10 Timing Requirements
    11. 7.11 Switching Characteristics
    12. 7.12 Typical Characteristics
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1  Undervoltage Protection
      2. 8.3.2  Insertion Delay
      3. 8.3.3  Overvoltage Protection
      4. 8.3.4  Inrush Current, Overcurrent, and Short-Circuit Protection
        1. 8.3.4.1 Slew rate (dVdt) and Inrush Current Control
          1. 8.3.4.1.1 Start-Up Timeout
        2. 8.3.4.2 Steady-State Overcurrent Protection (Circuit-Breaker)
        3. 8.3.4.3 Active Current Limiting During Start-Up
        4. 8.3.4.4 Short-Circuit Protection
      5. 8.3.5  Single Point Failure Mitigation
        1. 8.3.5.1 IMON Pin Single Point Failure
        2. 8.3.5.2 ILIM Pin Single Point Failure
        3. 8.3.5.3 IREF Pin Single Point Failure
      6. 8.3.6  Analog Load Current Monitor (IMON)
      7. 8.3.7  Overtemperature Protection
      8. 8.3.8  Analog Junction Temperature Monitor (TEMP)
      9. 8.3.9  FET Health Monitoring
      10. 8.3.10 General Purpose Digital Input/Output Pins
        1. 8.3.10.1 Fault Response and Indication (FLT)
        2. 8.3.10.2 Power Good Indication (PG)
        3. 8.3.10.3 Parallel Device Synchronization (SWEN)
      11. 8.3.11 Stacking Multiple eFuses for Unlimited Scalability
        1. 8.3.11.1 Current Balancing During Start-Up
      12. 8.3.12 General Purpose Comparators
      13. 8.3.13 Output Discharge
      14. 8.3.14 PMBus® Digital Interface
        1. 8.3.14.1  PMBus® Device Addressing
        2. 8.3.14.2  SMBus Protocol
        3. 8.3.14.3  SMBus™ Message Formats
        4. 8.3.14.4  Packet Error Checking
        5. 8.3.14.5  Group Commands
        6. 8.3.14.6  SMBus™ Alert Response Address (ARA)
        7. 8.3.14.7  PMBus® Commands
          1. 8.3.14.7.1 Detailed Descriptions of PMBus® Commands
            1. 8.3.14.7.1.1  OPERATION (01h, Read/Write Byte)
            2. 8.3.14.7.1.2  CLEAR_FAULTS (03h, Send Byte)
            3. 8.3.14.7.1.3  RESTORE_FACTORY_DEFAULTS (12h, Send Byte)
            4. 8.3.14.7.1.4  STORE_USER_ALL (15h, Send Byte)
            5. 8.3.14.7.1.5  RESTORE_USER_ALL (16h, Send Byte)
            6. 8.3.14.7.1.6  BB_ERASE (F5h, Send Byte)
            7. 8.3.14.7.1.7  FETCH_BB_EEPROM (F6h, Send Byte)
            8. 8.3.14.7.1.8  POWER_CYCLE (D9h, Send Byte)
            9. 8.3.14.7.1.9  MFR_WRITE_PROTECT (F8h, Read/Write Byte)
            10. 8.3.14.7.1.10 CAPABILITY (19h, Read Byte)
            11. 8.3.14.7.1.11 STATUS_BYTE (78h, Read Byte)
            12. 8.3.14.7.1.12 STATUS_WORD (79h, Read Word)
            13. 8.3.14.7.1.13 STATUS_OUT (7Ah, Read Byte)
            14. 8.3.14.7.1.14 STATUS_IOUT (7Bh, Read Byte)
            15. 8.3.14.7.1.15 STATUS_INPUT (7Ch, Read Byte)
            16. 8.3.14.7.1.16 STATUS_TEMP (7Dh, Read Byte)
            17. 8.3.14.7.1.17 STATUS_CML (7Eh, Read Byte)
            18. 8.3.14.7.1.18 STATUS_MFR_SPECIFIC (80h, Read Byte)
            19. 8.3.14.7.1.19 STATUS_MFR_SPECIFIC_2 (F3h, Read Word)
            20. 8.3.14.7.1.20 PMBUS_REVISION (98h, Read Byte)
            21. 8.3.14.7.1.21 MFR_ID (99h, Block Read)
            22. 8.3.14.7.1.22 MFR_MODEL (9Ah, Block Read)
            23. 8.3.14.7.1.23 MFR_REVISION (9Bh, Block Read)
            24. 8.3.14.7.1.24 READ_VIN (88h, Read Word)
            25. 8.3.14.7.1.25 READ_VOUT (8Bh, Read Word)
            26. 8.3.14.7.1.26 READ_IIN (89h, Read Word)
            27. 8.3.14.7.1.27 READ_TEMPERATURE_1 (8Dh, Read Word)
            28. 8.3.14.7.1.28 READ_VAUX (D0h, Read Word)
            29. 8.3.14.7.1.29 READ_PIN (97h, Read Word)
            30. 8.3.14.7.1.30 READ_EIN (86h, Block Read)
            31. 8.3.14.7.1.31 READ_VIN_AVG (DCh, Read Word)
            32. 8.3.14.7.1.32 READ_VIN_MIN (D1h, Read Word)
            33. 8.3.14.7.1.33 READ_VIN_PEAK (D2h, Read Word)
            34. 8.3.14.7.1.34 READ_VOUT_AVG (DDh, Read Word)
            35. 8.3.14.7.1.35 READ_VOUT_MIN (DAh, Read Word)
            36. 8.3.14.7.1.36 READ_IIN_AVG (DEh, Read Word)
            37. 8.3.14.7.1.37 READ_IIN_PEAK (D4h, Read Word)
            38. 8.3.14.7.1.38 READ_TEMP_AVG (D6h, Read Word)
            39. 8.3.14.7.1.39 READ_TEMP_PEAK (D7h, Read Word)
            40. 8.3.14.7.1.40 READ_PIN_AVG (DFh, Read Word)
            41. 8.3.14.7.1.41 READ_PIN_PEAK (D5h, Read Word)
            42. 8.3.14.7.1.42 READ_SAMPLE_BUF (D8h, Block Read)
            43. 8.3.14.7.1.43 READ_BB_RAM (FDh, Block Read)
            44. 8.3.14.7.1.44 READ_BB_EEPROM (F4h, Block Read)
            45. 8.3.14.7.1.45 BB_TIMER (FAh, Read Byte)
            46. 8.3.14.7.1.46 PMBUS_ADDR (FBh, Read/Write Byte)
            47. 8.3.14.7.1.47 VIN_UV_WARN (58h, Read/Write Word)
            48. 8.3.14.7.1.48 VIN_UV_FLT (59h, Read/Write Word)
            49. 8.3.14.7.1.49 VIN_OV_WARN (57h, Read/Write Word)
            50. 8.3.14.7.1.50 VIN_OV_FLT (55h, Read/Write Word)
            51. 8.3.14.7.1.51 VOUT_UV_WARN (43h, Read/Write Word)
            52. 8.3.14.7.1.52 VOUT_PGTH (5Fh, Read/Write Word)
            53. 8.3.14.7.1.53 OT_WARN (51h, Read/Write Word)
            54. 8.3.14.7.1.54 OT_FLT (4Fh, Read/Write Word)
            55. 8.3.14.7.1.55 PIN_OP_WARN (6Bh, Read/Write Word)
            56. 8.3.14.7.1.56 IIN_OC_WARN (5Dh, Read/Write Word)
            57. 8.3.14.7.1.57 VIREF (E0h, Read/Write Byte)
            58. 8.3.14.7.1.58 GPIO_CONFIG_12 (E1h, Read/Write Byte)
            59. 8.3.14.7.1.59 GPIO_CONFIG_34 (E2h, Read/Write Byte)
            60. 8.3.14.7.1.60 ALERT_MASK (DBh, Read/Write Word)
            61. 8.3.14.7.1.61 FAULT_MASK (E3h, Read/Write Word)
            62. 8.3.14.7.1.62 DEVICE_CONFIG (E4h, Read/Write Word)
            63. 8.3.14.7.1.63 BB_CONFIG (E5h, Read/Write Byte)
            64. 8.3.14.7.1.64 OC_TIMER (E6h, Read/Write Byte)
            65. 8.3.14.7.1.65 RETRY_CONFIG (E7h, Read/Write Byte)
            66. 8.3.14.7.1.66 ADC_CONFIG_1 (E8h, Read/Write Byte)
            67. 8.3.14.7.1.67 ADC_CONFIG_2 (E9h, Read/Write Byte)
            68. 8.3.14.7.1.68 PK_MIN_AVG (EAh, Read/Write Byte)
            69. 8.3.14.7.1.69 VCMPxREF (EBh, Read/Write Byte)
            70. 8.3.14.7.1.70 PSU_VOLTAGE (ECh, Read/Write Byte)
            71. 8.3.14.7.1.71 CABLE_DROP (EDh, Read/Write Byte)
            72. 8.3.14.7.1.72 GPDAC1 (F0h, Read/Write Byte)
            73. 8.3.14.7.1.73 GPDAC2 (F1h, Read/Write Byte)
            74. 8.3.14.7.1.74 INS_DLY (F9h, Read/Write Byte)
        8. 8.3.14.8  Analog-to-digital Converter
        9. 8.3.14.9  Digital-to-analog Converters
        10. 8.3.14.10 DIRECT format Conversion
        11. 8.3.14.11 Blackbox Fault Recording
    4. 8.4 Device Functional Modes
  10. Application and Implementation
    1. 9.1 Application Information
      1. 9.1.1 Single Device, Standalone Operation
      2. 9.1.2 Multiple Devices, Parallel Connection
      3. 9.1.3 Multiple Devices, Independent Operation (Multi-zone)
    2. 9.2 Typical Application: 12-V, 4-kW Power Path Protection with PMBus® Interface in Datacenter Servers
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Performance Plots
    3. 9.3 Best Design Practices
    4. 9.4 Power Supply Recommendations
      1. 9.4.1 Transient Protection
      2. 9.4.2 Output Short-Circuit Measurements
    5. 9.5 Layout
      1. 9.5.1 Layout Guidelines
      2. 9.5.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Documentation Support
      1. 10.1.1 Related Documentation
    2. 10.2 接收文档更新通知
    3. 10.3 支持资源
    4. 10.4 Trademarks
    5. 10.5 静电放电警告
    6. 10.6 术语表
  12. 11Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Group Commands

As required by PMBus® specification, TPS25990 supports the Group Command Protocol. The Group Command Protocol is used to send commands to more than one PMBus® target device. The commands are sent in one continuous transmission. When the target devices detect the STOP condition that ends the sending of commands, they all begin executing the command they received.

It is not necessary that all target devices receive the same command.

No more than one command can be sent to any one device in one Group Command packet.

The Group Command Protocol must not be used with commands that require the receiving device to respond with data, such as the STATUS_BYTE command.

The Group Command Protocol uses REPEATED START conditions to separate commands for each device. The Group Command Protocol begins with the START condition, followed by the seven bit address of the first target device to receive a command and then by the write bit zero (0). The secondary device ACKs and the host controller sends a command with the associated data byte or bytes.

After the last data byte is sent to the first device, the host controller does NOT send a STOP condition. Instead, it sends a REPEATED START condition, followed by the seven bit address of the second device to receive a command, a write bit and the command code and the associated data bytes.

If, and only if, this is the last target device to receive a command, the host controller sends a STOP condition. Otherwise, the host controller sends a REPEATED START condition and starts transmitting the address of the third device to receive a command.

This process continues until all target devices have received their command codes, data bytes, and if used and supported, PEC byte. Then when all target devices have received their information, the host controller sends a STOP condition.

If PEC is used, then each target device’s sub-packet has its own PEC byte, computed only for that device’s sub-packet, including that target device’s address.

When the target devices who have received a command through this protocol detect the STOP condition, they are to begin execution immediately of the received command.

When using Packet Error Checking with the Group Command Protocol, the PEC byte is calculated using only the address, command and data bytes for each target device. For example, PEC 1 is calculated using Device Address 1 including the Write bit, Command Code 1, and the data associated with Command Code 1. PEC 1 need only be calculated by the device at Device Address 1.

Similarly, PEC Byte 2 is calculated using Device Address 2 including the Write bit, Command Code 2, and the data associated with Command Code 2. Device 1 must not continue calculating PEC 1 after it sees the Repeated Start.