ZHCSOF7B september 2022 – june 2023 TPS25990
PRODUCTION DATA
RESTORE_FACTORY_DEFAULTS is a standard PMBus® command that initializes or resets all the configuration RAM registers to their hardware defaults. Read the INIT_DONE bit in the STATUS_MFR_SPECIFIC_2 register to check if initialization was completed successfully.
This command uses the PMBus® send byte protocol. There is no data byte for this command. This command is write only.
This command should be preceded by the MFR_WRITE_PROTECT command to unlock the device first to prevent accidental/spurious writes.