ZHCSS26F november   1998  – october 2020

PRODUCTION DATA  

  1.   1
  2. 特性
  3. 应用
  4. 说明
  5. Revision History
  6. Device Comparison Table
  7. Pin Configuration and Functions
    1. 6.1 Pin Functions
  8. Specifications
    1. 7.1  Absolute Maximum Ratings
    2. 7.2  ESD Ratings
    3. 7.3  Recommended Operating Conditions
    4. 7.4  Thermal Information
    5. 7.5  Electrical Characteristics
    6. 7.6  Electrical Characteristics for TPS3705-33 Only
    7. 7.7  Timing Requirements
    8. 7.8  Switching Characteristics
    9. 7.9  Dissipation Ratings
    10. 7.10 Timing Diagram
    11. 7.11 Typical Characteristics
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Manual Reset Input
      2. 8.3.2 Power-Fail Comparator
      3. 8.3.3 Watchdog Timer
    4. 8.4 Device Functional Modes
      1. 8.4.1 VDD < 1.1 V
      2. 8.4.2 1.1 V < VDD ≤ 2 V
      3. 8.4.3 2 V < VDD < 6 V
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curves
  11. 10Power Supply Recommendations
  12. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  13. 12Device and Documentation Support
    1. 12.1 接收文档更新通知
    2. 12.2 支持资源
    3. 12.3 Trademarks
    4. 12.4 静电放电警告
    5. 12.5 术语表
  14. 13Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Absolute Maximum Ratings

over operating free-air temperature range (unless otherwise noted)(1)
MINMAXUNIT
Supply voltage, VDD(2)7V
PFI voltage range, VPFI–0.3VDD + 0.3V
All other pins(2)–0.37V
Maximum low output current, IOL5mA
Maximum high output current, IOH–5mA
Input clamp current, IIK (VI < 0 or VI > VDD)±20mA
Output clamp current, IOK (VO < 0 or VO > VDD)±20mA
Continuous total power dissipationSee Section 7.9
Soldering temperature260°C
Operating temperature, TA–4085°C
Operating temperature, TA for TPS3705-33 only–40

125

°C
Storage temperature, Tstg–65150°C
Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
All voltage values are with respect to GND. For reliable operation the device must not be operated at 7 V for more than t = 1000h continuously.