ZHCSH96H MARCH 2007 – May 2019 TPS40192 , TPS40193
PRODUCTION DATA.
With output capacitance, it is possible to calculate the charge current during start-up and determine the minimum saturation current rating for the inductor. The start-up charging current is approximated by Equation 12.
PARAMETER | SYMBOL | VALUE | UNITS |
---|---|---|---|
Inductance | L | 1 | μH |
RMS current (thermal rating) | IL(rms) | 10.03 | A |
Peak current (saturation rating) | IL(peak) | 11.4 |
A PG0083.102 1-μH is selected for its small size, low DCR (6.6 mΩ) and high current handling capability (12 A thermal, 17 A saturation)