- Input overcurrent fault
(IIN_OCF) is a programmable threshold which sets the maximum allowed
input current for the converter. Detection is based on input current telemetry.
When the sensed input current exceeds this limit, the input overcurrent fault
condition is detected. Program this threshold using the IIN_OC_FAULT_LIMIT
command. TPS53676 supports values of 4 to 128A.
- Input overcurrent warning
(IIN_OCW) is a programmable threshold which sets a warning threshold for
the input current for the converter. Detection is based on input current
telemetry. When the sensed input current exceeds this limit, the input
overcurrent warning condition is detected. Program this threshold using the
IIN_OC_WARN_LIMIT command. TPS53676 supports values of 4 to 128A.
In response to the input overcurrent
fault, the TPS53676 responds according to the configured fault response in the
IIN_OC_FAULT_RESPONSE command. When not set to the ignore response, this causes the
PWM pins for both channels to tristate immediately. TPS53676 then sets the
appropriate status bits in STATUS_WORD and STATUS_INPUT and asserts the SMB_ALERT#
line if these bits are not masked.