ZHCSN24A August 2019 – May 2021 TPS53676
PRODUCTION DATA
Fault Name | Shared / Paged / Phased | Condition | Latency | Enabled | Programmable Range | Response | Alerts (1) | Clearing(2) |
---|---|---|---|---|---|---|---|---|
Output Voltage / Current / Power | ||||||||
Pre-Bias OV Fault | Shared | VSP voltage exceeded threshold | Max 350 µs after 3.3V OK | Until initialization complete, then disabled | 3.7 V fixed by design | All PWM Low, Latch-Off | VR_FAULT# | 3.3 V Power Cycle |
Fixed OV Fault | Paged | VSP voltage exceeded fixed threshold | 1.0 µs | After initialization complete | 0.6 V to 3.7 V | Ignore, Latch-Off, Hiccup PWM Pulled Low |
VR_FAULT# if not ignore response | 3.3 V power cycle if triggered while power conversion is disabled.
Otherwise, clearable through Enable cycle, or CLEAR_FAULTS |
Tracking OV Fault | Paged | VSP-VSN voltage exceeded VID + Droop + OV Offset | 1.0 µs | During power conversion | Offset from current VID+Droop, +32 to +448 mV Offset |
Ignore, Latch-Off, Hiccup PWM pulled low |
VR_FAULT# if not ignore response | Enable cycle, or CLEAR_FAULTS |
Tracking OV Warn | Paged | VSP-VSN voltage exceeded VID + Droop + OV Offset | 2.0 µs | During power conversion | Offset from current VID + Droop +24 to +448 mV Offset |
Warning only | n/a | Enable cycle, or CLEAR_FAULTS |
Tracking UV Warn | Paged | VSP-VSN voltage below VID + Droop - UV Offset | 2.0 µs | During power conversion | Offset from current VID + Droop -24 to -448 mV Offset |
Warning only | n/a | Enable cycle, or CLEAR_FAULTS |
Tracking UV Fault | Paged | VSP-VSN voltage below VID + Droop-UV Offset | 1.0 µs | During power conversion | Offset from current VID + Droop -32 to -448 mV Offset |
Ignore, Latch-Off, Hiccup PWM Tri-State |
n/a | Enable cycle, or CLEAR_FAULTS |
Max Turn-on time (TON_MAX) | Paged | VSP-VSN did not rise to threshold quickly enough during soft-start | 500 µs | During soft-start only | 0 ms to 31.75 ms | Ignore, Latch-Off, Hiccup PWM Tri-State |
n/a | Enable cycle, or CLEAR_FAULTS |
Vout Min/Max Warning | Paged | Vout commanded above VOUT_MAX or below VOUT_MIN | N/A | During power conversion | VOUT_MAX and VOUT_MIN |
DAC Voltage clamped to limit Warning only |
n/a | Enable cycle, or CLEAR_FAULTS |
Over-current Fault | Paged | Total current exceeded threshold | 175 µs | During power conversion | 0 to 1023 A(3) | Ignore, Latch-Off, Hiccup PWM Tri-State |
VR_FAULT# configurable | Enable cycle, or CLEAR_FAULTS |
Per-Phase Over-current Limit | Paged, Phased | Phase current exceeded threshold | Cycle-by-cycle | During power conversion | 17 to 130 A(3) | Warning only, PWM pulses skipped to limit phase current |
n/a | Enable cycle, or CLEAR_FAULTS |
Current Share Warning | Paged, Phased | Phase current above or below average current for all phases by threshold | 175 µs | During power conversion | 5 to 20 A per phase | Warning only | n/a | Enable cycle, or CLEAR_FAULTS |
Fault Name | Shared / Paged / Phased | Condition | Latency | Enabled | Programmable Range | Response | Alerts (1) | Clearing (2) |
---|---|---|---|---|---|---|---|---|
Power Stage Feedback | ||||||||
Over-Temperature Fault | Paged | Power Stage Temperature exceeded threshold | 950 µs | After initialization complete | +90 to +160 °C | Ignore, Latch-Off, Hiccup PWM Tri-State |
VR_FAULT# configurable | Enable cycle, or CLEAR_FAULTS |
Over-Temperature Warning | Paged | Power Stage Temperature exceeded threshold | 950 µs | After initialization complete | +90 to +160 °C | Warning only | n/a | Enable cycle, or CLEAR_FAULTS |
Power Stage Fault | Paged | TAO pulled high by power stage | 1.0 µs | After initialization complete | TAO > 2.5 V | Ignore, Latch-Off, Hiccup PWM Tri-State |
VR_FAULT# if not ignore response | Enable cycle, or CLEAR_FAULTS |
Power Stage Not Ready (TAO LOW) | Paged | TAO pulled low by power stage | 1.0 µs | After initialization complete | TAO < 230 mV Falling (50mV hysteresis) | Hysteresis Start-up is blocked if not yet enabled, or rail is shutdown. PWM tristated |
n/a | Enable cycle, or CLEAR_FAULTS |
Input Voltage / Current / Power | ||||||||
Input Over-Voltage Fault | Shared | VIN_CSNIN voltage exceeded threshold | 950 µs | After initialization complete | 0 to 19 V | Ignore, Latch-Off, Hiccup PWM Tri-State |
n/a | Enable cycle, or CLEAR_FAULTS |
Input Over-Voltage Warning | Shared | VIN_CSNIN voltage exceeded threshold | 950 µs | After initialization complete | 0 to 19 V | Warning only | n/a | Enable cycle, or CLEAR_FAULTS |
Input Under-Voltage Warning | Shared | VIN_CSNIN voltage below threshold | 950 µs | VIN > VIN_ON first time and either channel enabled | 4.0 to 11.25 V | Warning only | n/a | Enable cycle, or CLEAR_FAULTS |
Input Under-Voltage Fault | Shared | VIN_CSNIN voltage below threshold | 950 µs | VIN > VIN_ON first time and either channel enabled | 4.0 to 11.25 V | Ignore, Latch-Off, Hiccup PWM Tri-State |
n/a | Enable cycle, or CLEAR_FAULTS |
Input Over-Current Fault | Shared | CSPIN-VIN_CSNIN current below threshold | 525 µs | During power conversion | 4 to 128 A | Ignore, Latch-Off, Hiccup PWM Tri-State |
VR_FAULT# if not ignore response | Enable cycle, or CLEAR_FAULTS |
Input Over-Current Warning | Shared | CSPIN-VIN_CSNIN current below threshold | 525 µs | During power conversion | 4 to 128 A | Warning only | n/a | Enable cycle, or CLEAR_FAULTS |
Input Over-Power Warning | Shared | Computed input power above threshold | 525 µs | During power conversion | 8 to 2044 W | Warning only | n/a | Enable cycle, or CLEAR_FAULTS |
Self-Checking | ||||||||
Invalid ADDR Pinstrap | Shared | ADDR pin open, low, high, or non-convergent detection | Checked once at initialization | Checked during power-on and enable | Per detection thresholds | Latch-Off, PWM tristate | n/a | 3.3 V Power Cycle |
Invalid BOOT Pinstrap | Shared | BOOT pin open, low, high, or non-convergent detection | Checked once at initialization | Checked during power-on and enable | Per detection thresholds | Latch-Off, PWM tristate | n/a | 3.3 V Power Cycle |
PMBus Interface | ||||||||
PMBus Communication Error | Shared | PMBus Communication Error (See STATUS_CML) | Per PMBus communication frequency | After initialization complete | See PMBus Specification | Warning only | n/a | Enable cycle, or CLEAR_FAULTS |