ZHCSR16 September 2022 TPS544C26
ADVANCE INFORMATION
CMD Address | 4Fh |
Write Transaction: | Write Byte |
Read Transaction: | Read Byte |
Format: | Unsigned Binary (1 byte) |
NVM Backup: | EEPROM |
Updates: | On-the-fly |
The OT_FAULT_LIMIT command sets the temperature of the unit, at which, it indicates an overtemperature fault condition. The unit of this command is degrees Celsius. This feature utilizes a digital comparator that compares the output of the IC TEMPERATURE telemetry to the fault threshold selected in this register.
The device response to an overtemperature event is described in (50h) OT_FAULT_RESPONSE.
Return to Supported I2C and Default Values.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
R | R | R | R | R | R/W | R/W | R/W |
Reserved | SEL_OTF |
LEGEND: R/W = Read/Write; R = Read only |
Bit | Field | Access | Reset | Description |
---|---|---|---|---|
7:3 | Reserved | R | 00000b | Not used and always set to 0. |
2:0 | SEL_OTF | R/W | NVM | These bits select the OT fault threshold which is compared with
the output of the IC TEMP telemetry. 000b: OTF threshold = 115 °C 001b: OTF threshold = 120 °C 010b: OTF threshold = 125 °C 011b: OTF threshold = 130 °C 100b: OTF threshold = 135 °C 101b: OTF threshold = 140 °C 110b: OTF threshold = 145 °C 111b: OTF threshold = 150 °C |