ZHCSR16 September 2022 TPS544C26
ADVANCE INFORMATION
CMD Address | B4h |
Write Transaction: | Write Byte |
Read Transaction: | Read Byte |
Format: | Unsigned Binary (1 byte) |
NVM Backup: | EEPROM |
Updates: | On-the-fly |
The IOUT_NOC_LIMIT command contains 3 fields for configuring the VOUT Fixed OVF and Neagive Overcurrent (NOC) limit selection.
The SEL_FIX_OVF bit sets the value of the output voltage measured at the (VOSNS − GOSNS) pins that causes an output overvoltage fault. The Fixed OVF function sets a constant overvoltage threshold that has no relationship to the current VOUT setting. The VOUT Fixed OVF is active as soon as the TPS544C26 device completes its power-on reset, even if the output conversion is disabled.
Following a Fixed OVF condition, the device always latches OFF high-side MOSFET and latches ON low-side MOSFET. The response setting in (41h) VOUT_OV_FAULT_RESP register does not affect the response for a Fixed OVF condition.
The VOUT Fixed OVF feature can be disabled through the EN_FIX_OVF bit.
The NOC threshold which scales with ICC_MAX setting (see (C0h) ICC_MAX) is selected by SEL_NOC field.
Return to Supported I2C and Default Values.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
R | R | R | R | R/W | R/W | R/W | R/W |
Reserved | SEL_FIX_OVF | EN_FIX_OVF | SEL_NOC |
LEGEND: R/W = Read/Write; R = Read only |
Bit | Field | Access | Reset | Description |
---|---|---|---|---|
7:4 | Reserved | R | 0000b | Not used and always set to 0. |
3 | SEL_FIX_OVF | R/W | NVM | Select the VOUT Fixed OVF thresholds. See details on Table 7-74. |
2 | EN_FIX_OVF | R/W | NVM |
0b: Enable the VOUT Fixed OVF 1b: Disable the VOUT Fixed OVF |
1:0 | SEL_NOC | R/W | NVM | Select the Negative Overcurrent limits which scale with ICC_MAX setting. See details on Table 7-75. |
PROTOCOL_ID in (C2h) PROTOCOL_ID_SVID | SEL_FIX_OVF[1] in (B4h) IOUT_NOC_LIMIT | VOUT Fixed OVF threshold (V) |
---|---|---|
PROTOCOL_ID = 01b or 10b (VOUT step = 5 mV) | 0 | 1.5 |
PROTOCOL_ID = 01b or 10b (VOUT step = 5 mV) | 1 | 1.8 |
PROTOCOL_ID = 00b or 11b (VOUT step = 10 mV) | 0 | 2.4 |
PROTOCOL_ID = 00b or 11b (VOUT step = 10 mV) | 1 | 3.0 |
SEL_NOC[1:0] | Negative Overcurrent Limits (A) | |
---|---|---|
ICC_MAX ≥ 15 A | ICC_MAX ≤ 10 A | |
00 | −20 | −10 |
01 | −15 | −7.5 |
10 | −12 | −6 |
11 | −10 | −5 |