7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
OCF | OCUVF | Not Used | UCF | Not Used | |||
R | R | R | R | R |
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7 | OCF | R | N/A | 0: An output positive overcurrent fault has not occurred 1: An output positive overcurrent fault has occurred |
6 | OCUVF | R | N/A | 0: A simultaneous output positive overcurrent and undervoltage fault has not occurred 1: A simultaneous output positive overcurrent and undervoltage fault has occurred |
5 | Not Used | R | N/A | Not Used |
4 | UCF | R | N/A | 0: An output negative overcurrent fault has not occurred 1: An output negative overcurrent fault has occurred |
3:0 | Not Used | R | N/A | Not Used |