ZHCSHS6F November 2017 – November 2024
PRODUCTION DATA
请参考 PDF 数据表获取器件具体的封装图。
A feedforward capacitor (C4) is required in parallel with R1. Equation 4 calculates the capacitor value. For the recommended 100 k value for R2, a 120 pF feedforward capacitor is used. For forced PWM devices, a feedforward capacitor is not needed.