ZHCSI09S June 2010 – August 2018 TPS65911
PRODUCTION DATA.
A write access is initiated by a first byte including the address of the device (7 MSBs) and a write command (LSB), a second byte provides the address (8 bits) of the internal register, and the third byte represents the data to be written in the internal register, see Figure 6-7.
A read access is initiated by:
The device replies by sending a fourth byte representing the content of the internal register (see
Figure 6-8).