6.1 Absolute Maximum Ratings
At TJ = –40°C to 125°C (unless otherwise noted). All voltages are with respect to GND.(1)
|
MIN |
MAX |
UNIT |
VIN(2) |
Input voltage (steady-state) |
–0.3 |
VBIAS or 5(3) |
V |
VIN_PEAK(4) |
Peak transient input |
|
5.5 |
V |
VBIAS |
Bias voltage |
–0.3 |
6 |
V |
VEN |
Enable voltage |
–0.3 |
6 |
V |
VOUT |
Output voltage |
–0.3 |
5 |
V |
IOUT |
Peak output current |
Internally limited |
|
|
Output short circuit duration |
Indefinite |
|
PDISS |
Total continuous power dissipation |
See Thermal Information |
|
TJ |
Operating junction temperature |
–55 |
125 |
°C |
Tstg |
Storage temperature |
–55 |
150 |
°C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) To ensure proper operation of the device it is necessary that VIN ≤ VBIAS under all conditions.
(3) Whichever is less.
(4) For durations no longer than 1ms each, for a total of no more than 1000 occurrences over the lifetime of the device.