6.1 Absolute Maximum Ratings
At –40°C ≤ TJ and TA ≤ 125°C (unless otherwise noted). All voltages are with respect to GND.(1)
|
MIN |
MAX |
UNIT |
Voltage |
VIN |
–0.3 |
7 |
V |
VEN |
–0.3 |
VIN + 0.3 |
V |
VFB |
–0.3 |
1.6 |
V |
VOUT |
–0.3 |
VIN + 0.3 |
V |
Current |
IOUT |
Internally limited |
A |
Continuous total power dissipation |
Continuous, PD(tot) |
See the Power Dissipation section |
|
Operating junction temperature, TJ |
–40 |
150 |
°C |
Storage temperature, Tstg |
–55 |
150 |
°C |
(1) Stresses beyond those listed as absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated as recommended operating conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.