ZHCSMC2V September 2003 – September 2024 TPS736
PRODUCTION DATA
The TPS736 internal current limit helps protect the regulator during fault conditions. Foldback current limit helps to protect the regulator from damage during output short-circuit conditions by reducing current limit when VOUT drops below 0.5 V. See Figure 5-17 in the Typical Characteristics section.