over operating free-air temperature range (unless otherwise noted)(1) | MIN | MAX | UNIT |
---|
VIN | Input voltage
range | IN(2) | –65 | 60 | V |
OUT | –0.3 | 28 |
FB | –0.3 | 7 |
EN(2) | –65 | 60 |
Enable to IN
differential | 0.6 | VIN |
TJ | Junction
temperature range(3) | –40 | 125 | °C |
Tstg | Storage
temperature | –65 | 150 | °C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Transient: 500ms for VIN > 50V.
(3) The junction temperature must not exceed 125°C. See
Figure 5-13 to determine the maximum ambient operating temperature versus the supply
voltage and load current. The safe operating area curves assume a 50°C/W thermal
impedance and may need to be adjusted to match actual system thermal
performance.