over operating junction temperature range (unless otherwise noted). (1)
|
MIN |
NOM |
MAX |
UNIT |
VIN |
Input voltage |
0.7 |
|
2.2 |
V |
VBIAS |
Bias voltage |
Greater of 2.2 or VOUT + 1.4 |
|
5.5 |
V |
VOUT |
Output voltage |
0.5 |
|
2.05 |
V |
IOUT |
Peak output current |
0 |
|
300 |
mA |
CIN |
Input capacitance(2) |
0.75 |
|
|
µF |
CBIAS |
Bias capacitance(3) |
|
0.1 |
|
µF |
COUT |
Output capacitance |
1 |
|
47 |
µF |
ESR |
Output capacitor series resistance |
|
|
100 |
mΩ |
TJ |
Operating junction temperature |
–40 |
|
125 |
℃ |
(1) All voltages are with respect to GND.
(2) An input capacitor is required to counteract the effect of source resistance and inductance, which may in some cases cause symptoms of system level instability such as ringing or oscillation, especially in the presence of load transients. A larger input capacitor may be necessary depending on the source impedance and system requirements.