SUPPLY VOLTAGE AND CURRENT |
VIN |
Input voltage |
VOUT ≤ 3.5 V , IOUT = 0 mA to 450 mA |
4 |
|
40 |
V |
VOUT ≥ 3.5 V , IOUT = 0 mA to 450 mA |
VOUT + 0.5 |
|
40 |
V |
IQ |
Quiescent current |
VIN = 4 V to 40 V, VOUT = 1.5 V, VEN = 5 V, IOUT = 0.2 mA |
|
15 |
25 |
µA |
VIN = 18.5 V to 40 V, VOUT = 18 V, VEN = 5 V, IOUT = 0.2 mA |
|
25 |
40 |
ISHDN |
Shutdown current |
VEN = 0 V, IOUT = 0 mA , VIN = 18 V, VOUT = 1.5 V |
|
|
4 |
µA |
VFB |
Feedback voltage |
Reference voltage for FB pin |
1.208 |
1.233 |
1.258 |
V |
VIN_UVLO |
Undervoltage lockout |
Ramp VIN down until output is turned off |
|
|
2.6 |
V |
UVLOHys |
Undervoltage detection hysteresis |
VIN rising |
|
1 |
|
V |
ENABLE INPUT (EN) |
VEN_LO |
Logic input low level |
|
0 |
|
0.4 |
V |
VEN_HI |
Logic input high level |
|
1.7 |
|
|
V |
IEN |
EN pin current |
VEN = 40 V , VIN = 14 V |
|
|
1 |
µA |
REGULATED OUTPUT |
VOUT |
Regulated output(1) |
VIN = VOUT + 1 V to 40 V and VIN ≥ 4 V, IOUT = 100 µA to 450 mA |
–2% |
|
2% |
|
ΔVO(ΔVI) |
Line regulation |
VIN = VOUT + 1 V to 40 V and VIN ≥ 4 V, IOUT = 100 mA |
|
|
10 |
mV |
ΔVO(ΔIL) |
Load regulation |
IOUT = 1 mA to 450 mA, VIN = VOUT + 1 V and VIN ≥ 4 V |
|
|
10 |
mV |
VDO |
Dropout voltage |
VIN – VOUT, IOUT = 400 mA |
|
240 |
450 |
mV |
VIN – VOUT, IOUT = 200 mA |
|
160 |
300 |
IOUT |
Output current |
VOUT in regulation |
0 |
|
450 |
mA |
ICL |
Output current-limit |
VOUT short to ground |
140 |
|
360 |
mA |
VOUT = VOUT nominal × 0.9 |
470 |
|
850 |
PSRR |
Power-supply ripple rejection(2) |
IOUT = 100 mA, COUT = 22 µF |
f = 100 Hz |
|
60 |
|
dB |
f = 100 kHz |
|
40 |
|
PG |
VOL |
PG output low voltage |
IOL = 0.5 mA |
|
|
0.4 |
V |
IOH |
PG leakage current |
PG pulled to VOUTwith 10-kΩ resistor |
|
|
1 |
µA |
VT(PG) |
Power good threshold |
VOUT power-up |
89.6 |
91.6 |
93.6 |
% of VOUT |
Vhys |
Hysteresis |
VOUT power-down |
|
2 |
|
% of VOUT |
PG DELAY |
IDelay |
Delay capacitor charging current |
|
5 |
9.5 |
14 |
µA |
VT(PG_DLY) |
Delay pin comparator threshold voltage |
|
|
1 |
|
V |
TEMPERATURE |
Tsd |
Junction shutdown temperature |
Temperature increasing |
|
175 |
|
°C |
Thys |
Hysteresis of thermal shutdown |
|
|
24 |
|