over operating free-air temperature range (unless otherwise noted)(1)
|
MIN |
MAX |
UNIT |
Voltage(2) |
VIN |
–0.3 |
85(3) |
V |
VOUT (adjustable version) |
–0.3 |
VMID + 0.3(4) |
VOUT (fixed version) |
–0.3 |
5.5 |
VMID_OUT |
–0.3 |
VIN + 0.3(5) |
VFB |
–0.3 |
5.5 |
VEN |
–0.3 |
20 |
VMVSEL1 |
–0.3 |
20 |
VMVSEL2 |
–0.3 |
20 |
VPG |
–0.3 |
20 |
Current |
Maximum output |
Internally limited |
A |
Maximum MID output |
Internally limited |
Temperature |
Operating junction, TJ |
–50 |
150 |
°C |
Storage, Tstg |
–65 |
150 |
(1) Operation outside the Absolute Maximum Ratings may cause permanent device damage. Absolute Maximum Ratings do not imply functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If briefly operating outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device may not sustain damage, but it may not be fully functional – this may affect device reliability, functionality, performance, and shorten the device lifetime.
(2) All voltages with respect to GND.
(3) Absolute maximum voltage, withstand 85 V for 200 ms.
(4) VMID_OUT + 0.3 V or 20 V (whichever is smaller).
(5) VIN + 0.3 V or 20 V (whichever is smaller).