over operating junction temperature range (unless otherwise noted)(1)
|
MIN |
MAX |
UNIT |
Voltage |
IN, PG,
EN |
–0.3 |
7 |
V |
SS, FB, SNS,
OUT |
–0.3 |
VIN + 0.3(2) |
V |
50 mV, 100
mV, 200 mV, 400 mV, 800 mV, 1.6 V |
–0.3 |
VOUT + 0.3(2) |
V |
Current |
OUT |
Internally
limited |
A |
PG (sink
current into IC) |
|
5 |
mA |
Temperature |
Operating
virtual junction, TJ |
–55 |
160 |
°C |
Storage,
Tstg |
–55 |
150 |
°C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.