A. Rise and fall times of the control signal
are 100
ns.
B. Turn-off times and fall times are
dependent on the time constant at the load. For the TPS7H2221-SEP, the internal pull-down
resistance QOD is enabled when the switch is disabled. When QOD is connected to OUT
using
a resistor (RQOD),
the time constant is (RQOD + RPD,QOD ||
ROUT) × COUT.