VIN |
C3 |
IN |
Input voltage supply pin of the module. |
GND |
C2 |
- |
Ground terminal. |
CTRL |
B2 |
IN |
CTRL pin controls the LOAD output pin. With CTRL = low, the LOAD output is disabled. This pin must be terminated and not left floating. |
VOUT |
C1 |
OUT |
Output voltage pin of the module. An internal load switch is connected between VOUT pin and LOAD pin. |
LOAD |
B1 |
OUT |
Load switch output pin controlled by the CTRL pin. With CTRL = high, an internal load switch connects the LOAD pin to the VOUT pin. The LOAD pin allows connect / disconnect other system components to the output of the DC/DC converter. This pin is pulled to GND with the CTRL pin = low. The LOAD pin features soft switching. If not used, leave the pin open. |
VSEL3 |
A1 |
IN |
Output voltage selection pins. See Table 2 and Table 3 for VOUT selection. These pins must be terminated and can be changed during operation. |
VSEL2 |
A2 |
IN |
VSEL1 |
A3 |
IN |
EN |
B3 |
IN |
High level enables the devices and low level turns the device into shutdown mode. This pin must be terminated and not left floating. |