SLUSCZ1 May 2017 TPS92518-Q1
PRODUCTION DATA.
The TPS92518-Q1 can be configured to operate as a Two Channel, Single Output converter by configuring each channel identically and connecting the outputs together. Figure 30 illustrates the current sharing capability with each channel handling approximately the equal share of the output current load. Statistics are enabled and the average inductor current of each channel is also shown. The total output current for this configuration is 438 mA. Note that both channels must be enabled at the same time to allow charging of the boot capacitors. When a channel is paralleled, it may not be enabled after the first channel is enabled.
CH4 (Green) : Inductor Current (100 mA per division) | CH1 (Blue) : SW1 Node (50 V per division) |
CH2 (Cyan) : Inductor Current (100 mA per division) |