ZHCSHB3B January 2018 – January 2020 TPS92611-Q1
PRODUCTION DATA.
When the device drives an LED string in low-dropout mode, if the voltage drop is less than the open-circuit detection threshold, the device may report a false open. Set the DIAGEN threshold higher than the LED string voltage to avoid a false open-circuit detection.