The TPS92643-Q1 uses an adaptive on-time control scheme and does not have a dedicated on-board oscillator. The one-shot timer is programmed by the RON resistor. The on-time is calculated internally using Equation 1 and is inversely proportional to the measured input voltage, VIN, and directly proportional to the measured CSP voltage, VCSP.
Given the duty ratio of the buck converter is VCSP/VIN, the switching period, TSW, remains nearly constant over different operating points. Use Equation 2 to calculate the switching period.
The switching frequency is calculated internally using Equation 3.
The minimum or maximum duty cycle is limited to finite minimum on-time, TON(MIN) and minimum off-time, TOFF(MIN), respectively. As on-time is constant, the frequency is also a dependent on the efficiency of the device, ηREG, excluding inductor and sense resistor losses.
TI recommends a switching frequency setting between 100 kHz and 2.2 MHz.