ZHCSIO9A August   2018  – June 2021 TPSM831D31

PRODUCTION DATA  

  1. 特性
  2. 应用
  3. 说明
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Electrical Characteristics
    6. 6.6  References: DAC
    7. 6.7  Telemetry
    8. 6.8  Current Sense and Calibration
    9. 6.9  Logic Interface Pins: A_EN, A_PGOOD, B_EN, B_PGOOD,RESET
    10. 6.10 Protections: OVP and UVP
    11. 6.11 Typical Characteristics (VIN = 12 V)
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 DCAP+ Control
      2. 7.3.2 Setting the Load-Line (DROOP)
      3. 7.3.3 Start-Up Timing
      4. 7.3.4 Load Transitions
      5. 7.3.5 Switching Frequency
      6. 7.3.6 RESET Function
      7. 7.3.7 VID Table
    4. 7.4 Device Functional Modes
      1. 7.4.1 Continuous Conduction Mode
      2. 7.4.2 Operation With EN Signal Control
      3. 7.4.3 Operation With OPERATION Control
      4. 7.4.4 Operation With EN and OPERATION Control
    5. 7.5 Programming
      1. 7.5.1  PMBus Connections
      2. 7.5.2  PMBus Address Selection
      3. 7.5.3  Supported Commands
      4. 7.5.4  Commonly Used PMBus Commands
      5. 7.5.5  Voltage, Current, Power, and Temperature Readings
        1. 7.5.5.1 (88h) READ_VIN
        2. 7.5.5.2 (89h) READ_IIN
        3. 7.5.5.3 (8Bh) READ_VOUT
        4. 7.5.5.4 (8Ch) READ_IOUT
        5. 7.5.5.5 (8Dh) READ_TEMPERATURE_1
        6. 7.5.5.6 (96h) READ_POUT
        7. 7.5.5.7 (97h) READ_PIN
        8. 7.5.5.8 (D4h) MFR_SPECIFIC_04
      6. 7.5.6  Output Current Sense and Calibration
        1. 7.5.6.1 Reading Individual Phase Currents
          1. 7.5.6.1.1 Reading Total Current
          2. 7.5.6.1.2 51
      7. 7.5.7  Output Voltage Margin Testing
        1. 7.5.7.1 (01h) OPERATION
        2. 7.5.7.2 (26h) VOUT_MARGIN_LOW
        3. 7.5.7.3 (25h) VOUT_MARGIN_HIGH
      8. 7.5.8  Loop Compensation
        1. 7.5.8.1 (D7h) MFR_SPECIFIC_07
        2. 7.5.8.2 (28h) VOUT_DROOP
      9. 7.5.9  Converter Protection and Response
      10. 7.5.10 Output Overvoltage Protection and Response
        1. 7.5.10.1 (40h) VOUT_OV_FAULT_LIMIT
        2. 7.5.10.2 (41h) VOUT_OV_FAULT_RESPONSE
      11. 7.5.11 Maximum Allowed Output Voltage Setting
        1. 7.5.11.1 (24h) VOUT_MAX
      12. 7.5.12 Output Undervoltage Protection and Response
        1. 7.5.12.1 (44h) VOUT_UV_FAULT_LIMIT
        2. 7.5.12.2 (45h) VOUT_UV_FAULT_RESPONSE
      13. 7.5.13 Minimum Allowed Output Voltage Setting
        1. 7.5.13.1 (2Bh) VOUT_MIN
      14. 7.5.14 Output Overcurrent Protection and Response
        1. 7.5.14.1 (46h) IOUT_OC_FAULT_LIMIT
        2. 7.5.14.2 (4Ah) IOUT_OC_WARN_LIMIT
        3. 7.5.14.3 (47h) IOUT_OC_FAULT_RESPONSE
        4. 7.5.14.4 Per Phase Overcurrent Limit Thresholds
      15. 7.5.15 Input Under-Voltage Lockout (UVLO)
        1. 7.5.15.1 (35h) VIN_ON
      16. 7.5.16 Input Over-Voltage Protection and Response
        1. 7.5.16.1 (55h) VIN_OV_FAULT_LIMIT
        2. 7.5.16.2 (56h) VIN_OV_FAULT_RESPONSE
      17. 7.5.17 Input Undervoltage Protection and Response
        1. 7.5.17.1 (59h) VIN_UV_FAULT_LIMIT
        2. 7.5.17.2 (5Ah) VIN_UV_FAULT_RESPONSE
      18. 7.5.18 Input Overcurrent Protection and Response
        1. 7.5.18.1 (5Bh) IIN_OC_FAULT_LIMIT
        2. 7.5.18.2 (5Dh) IIN_OC_WARN_LIMIT
        3. 7.5.18.3 (5Ch) IIN_OC_FAULT_RESPONSE
      19. 7.5.19 Overtemperature Protection and Response
        1. 7.5.19.1 (4Fh) OT_FAULT_LIMIT
        2. 7.5.19.2 (51h) OT_WARN_LIMIT
        3. 7.5.19.3 (50h) OT_FAULT_RESPONSE
      20. 7.5.20 Dynamic Phase Shedding (DPS)
        1. 7.5.20.1 (DEh) MFR_SPECIFIC_14
        2. 7.5.20.2 (DFh) MFR_SPECIFIC_15
      21. 7.5.21 NVM Programming
      22. 7.5.22 NVM Security
        1. 7.5.22.1 (FAh) MFR_SPECIFIC_42
      23. 7.5.23 Black Box Recording
        1. 7.5.23.1 (D8h) MFR_SPECIFIC_08
      24. 7.5.24 Board Identification and Inventory Tracking
      25. 7.5.25 Status Reporting
        1. 7.5.25.1 (78h) STATUS_BYTE
        2. 7.5.25.2 (79h) STATUS_WORD
        3. 7.5.25.3 (7Ah) STATUS_VOUT
        4. 7.5.25.4 (7Bh) STATUS_IOUT
        5. 7.5.25.5 (7Ch) STATUS_INPUT
        6. 7.5.25.6 (7Dh) STATUS_TEMPERATURE
        7. 7.5.25.7 (7Eh) STATUS_CML
        8. 7.5.25.8 (80h) STATUS_MFR_SPECIFIC
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Input Capacitors
        2. 8.2.2.2 Output Capacitors
        3. 8.2.2.3 Switching Frequency
        4. 8.2.2.4 Set PMBus Address
        5. 8.2.2.5 PMBus GUI Default Values
      3. 8.2.3 Application Performance Plots
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
    2. 10.2 Layout Examples
  11. 11Device and Documentation Support
    1. 11.1 接收文档更新通知
    2. 11.2 支持资源
    3. 11.3 Trademarks
    4. 11.4 静电放电警告
    5. 11.5 术语表
  12. 12Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
  • MOA|28
散热焊盘机械数据 (封装 | 引脚)
订购信息

(7Ah) STATUS_VOUT

The STATUS_VOUT command returns one byte of information relating to the status of the converter's output voltage related faults.

The STATUS_VOUT command must be accessed through Read Byte/Write Byte transactions. STATUS_VOUT is a paged register. In order to access STATUS_VOUT command for channel A, PAGE must be set to 00h. In order to access STATUS_VOUT register for channel B, PAGE must be set to 01h. If PAGE is set FFh, the device return value will reflect the status of Channel A.

Figure 7-6 STATUS_VOUT
76543210
RW00RWRW000
VOUT_OVFVOUT_OVWVOUT_UVWVOUT_UVFVOUT_MIN_MAXTON_MAXTOFF_MAXVOUT_TRACK
Table 7-64 STATUS_VOUT Register Field Descriptions
BitFieldTypeResetDescription
7VOUT_OVFRWCurrent
Status
Output Over-Voltage Fault
0: Latched flag indicating no VOUT OV fault has occurred.
1: Latched flag indicating a VOUT OV fault has occurred.
6VOUT_OVWR0Not supported and always set to 0.
5VOUT_UVWR0Not supported and always set to 0.
4VOUT_UVFRWCurrent
Status
Output Under-Voltage Fault
0: Latched flag indicating no VOUT UV fault has occurred.
1: Latched flag indicating a VOUT UV fault has occurred.
3VOUT_MIN_MAXRWCurrent
Status
Output Voltage Max/Min Exceeded Warning
0: Latched flag indicating no VOUT_MAX/VOUT_MIN warning has occurred.
1: Latched flag indicating that an attempt has been made to set the output voltage to a value higher than allowed by the VOUT_MAX/VOUT_MIN command.
2TON_MAXR0Not supported and always set to 0.
1TOFF_MAXR0Not supported and always set to 0.
0VOUT_TRACKR0Not supported and always set to 0.

Per the description in the PMBus 1.3 specification, part II, TPSM831D31 does support clearing of status bits by writing to STATUS registers. Writing a 1 to any supported bit in this register will attempt to clear it as a fault condition.