The VIN_UV_FAULT_LIMIT command sets the value of the input voltage that causes an Input Under voltage Fault. This fault is masked until the input exceeds the value set by the VIN_ON command for the first time, and the unit has been enabled. VIN_UV_FAULT_LIMIT is a linear format command, and must be accessed through Read Word/Write Word transactions. The VIN_UV_FAULT_LIMIT command is shared between Channel A and Channel B. All transactions to this command will affect both channels regardless of the PAGE command.
VIN_UV_FAULT_LIMIT15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
RW | RW | RW | RW | RW | RW | RW | RW |
VIN_UVF_EXP | VIN_UVF_MAN |
|
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
RW | RW | RW | RW | RW | RW | RW | RW |
VIN_UVF_MAN |
LEGEND: R/W = Read/Write; R = Read only |
Table 7-44 VIN_UV_FAULT_LIMIT Register Field DescriptionsBit | Field | Type | Reset | Description |
---|
15:11 | VIN_UVF_EXP | RW | NVM | Linear two's complement exponent. See the table of
acceptable values below. |
10:0 | VIN_UVF_MAN | RW | NVM | Linear two's complement mantissa. See the table of
acceptable values below. |
Table 7-45 Acceptable Values of VIN_UV_FAULT_LIMITVIN_UV_FAULT_LIMIT (hex) | VIN UVF Limit (V) |
---|
F80Dh | 6.5 |
F80Fh | 7.5 |
F811h | 8.5 |
F813h | 9.5 |
F815h | 10.5 |
F817h | 11.5 |