ZHCS266F June 2011 – May 2017 TRF7960A
PRODUCTION DATA.
The transmission command must be sent first, followed by the transmission length bytes, and FIFO data. The reader transmission is triggered by the TX timer. This is the same as described in Section 6.13.5, except that the CRC is not included.