over operating free-air temperature range (unless otherwise noted) (1)(2) | MIN | MAX | UNIT |
---|
VCC | Supply voltage(3) | –0.5 | 4 | V |
VNC VNO VCOM | Signal voltage(3)(4) | –0.5 | VCC + 0.5 | V |
II/OK | Analog port diode current | VNC, VNO, VCOM < 0 | –50 | 50 | mA |
INC INO ICOM | ON-state switch current | VNC, VNO, VCOM = 0 to VCC | –300 | 300 | mA |
ON-state peak switch current(5) | –500 | 500 |
VIN | Digital input voltage | –0.5 | 3.6 | V |
IIK | Digital input clamp current(3) | VI < 0 | –50 | | mA |
ICC | Continuous current through VCC | | 100 | mA |
IGND | Continuous current through GND | –100 | | mA |
Tstg | Storage temperature | –65 | 150 | °C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum.
(3) All voltages are with respect to ground, unless otherwise specified.
(4) This value is limited to 5.5 V maximum.
(5) Pulse at 1-ms duration <10% duty cycle.