ZHCS023D January   2010  – October 2022 TS3A27518E-Q1

PRODUCTION DATA  

  1. 特性
  2. 应用
  3. 说明
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics for 3.3-V Supply
    6. 6.6 Electrical Characteristics for 2.5-V Supply
    7. 6.7 Electrical Characteristics for 1.8-V Supply
    8. 6.8 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
    4. 8.4 Device Functional Modes
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirement
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curves
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 接收文档更新通知
    3. 12.3 支持资源
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 术语表
  13. 13Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Parameter Measurement Information

Table 7-1 Parameter Description
SYMBOL DESCRIPTION
VCOM Voltage at COM
VNC Voltage at NC
VNO Voltage at NO
ron Resistance between COM and NC or NO ports when the channel is ON
Δron Difference of ron between channels in a specific device
ron(flat) Difference between the maximum and minimum value of ron in a channel over the specified range of conditions
INC(OFF) Leakage current measured at the NC port, with the corresponding channel (NC to COM) in the OFF state
INC(ON) Leakage current measured at the NC port, with the corresponding channel (NC to COM) in the ON state and the output (COM) open
INO(OFF) Leakage current measured at the NO port, with the corresponding channel (NO to COM) in the OFF state
INO(ON) Leakage current measured at the NO port, with the corresponding channel (NO to COM) in the ON state and the output (COM) open
ICOM(OFF) Leakage current measured at the COM port, with the corresponding channel (COM to NC or NO) in the OFF state
ICOM(ON) Leakage current measured at the COM port, with the corresponding channel (COM to NC or NO) in the ON state and the output (NC or NO) open
VIH Minimum input voltage for logic high for the control input (IN, EN)
VIL Maximum input voltage for logic low for the control input (IN, EN)
VI Voltage at the control input (IN, EN)
IIH, IIL Leakage current measured at the control input (IN, EN)
tON Turn-on time for the switch. This parameter is measured under the specified range of conditions and by the propagation delay between the digital control (IN) signal and analog output NC or NO) signal when the switch is turning ON.
tOFF Turn-off time for the switch. This parameter is measured under the specified range of conditions and by the propagation delay between the digital control (IN) signal and analog output (NC or NO) signal when the switch is turning OFF.
QC Charge injection is a measurement of unwanted signal coupling from the control (IN) input to the analog (NC or NO) output. This is measured in coulomb (C) and measured by the total charge induced due to switching of the control input. Charge injection, QC = CL × ΔVCOM, CL is the load capacitance and ΔVCOM is the change in analog output voltage.
CNC(OFF) Capacitance at the NC port when the corresponding channel (NC to COM) is OFF
CNC(ON) Capacitance at the NC port when the corresponding channel (NC to COM) is ON
CNO(OFF) Capacitance at the NC port when the corresponding channel (NO to COM) is OFF
CNO(ON) Capacitance at the NC port when the corresponding channel (NO to COM) is ON
CCOM(OFF) Capacitance at the COM port when the corresponding channel (COM to NC) is OFF
CCOM(ON) Capacitance at the COM port when the corresponding channel (COM to NC) is ON
CI Capacitance of control input (IN, EN)
OISO OFF isolation of the switch is a measurement of OFF-state switch impedance. This is measured in dB in a specific frequency, with the corresponding channel (NC to COM) in the OFF state.
XTALK Crosstalk is a measurement of unwanted signal coupling from an ON channel to an OFF channel (NC1 to NO1). Adjacent crosstalk is a measure of unwanted signal coupling from an ON channel to an adjacent ON channel (NC1 to NC2) .This is measured in a specific frequency and in dB.
BW Bandwidth of the switch. This is the frequency in which the gain of an ON channel is –3 dB below the DC gain.
THD Total harmonic distortion describes the signal distortion caused by the analog switch. This is defined as the ratio of root mean square (RMS) value of the second, third, and higher harmonic to the absolute magnitude of the fundamental harmonic.
I+ Static power-supply current with the control (IN) pin at V+ or GND
GUID-5795C267-BAA8-4D82-83D0-9765172A9BB2-low.gif Figure 7-1 ON-state Resistance (rON)
GUID-ED862979-D587-450F-8AAC-955AFD25D2E5-low.gif Figure 7-2 OFF-State Leakage Current (ICOM(OFF), INC(OFF), ICOM(PWROFF), INC(PWROFF))
GUID-6FD614D5-190F-4A77-A845-8F0D8B937D38-low.gif Figure 7-3 ON-State Leakage Current (ICOM(ON), INC(ON))
GUID-D5595127-A859-466C-A57E-37E791571C59-low.gif Figure 7-4 Capacitance (CI, CCOM(OFF), CCOM(ON), CNC(OFF), CNC(ON))
GUID-5C989CE5-9A1E-4F52-AF1F-1DD1119B834E-low.gif
All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr < 5 ns, tf < 5 ns.
CL includes probe and jig capacitance.
Figure 7-5 Turn-On (tON) and Turn-Off Time (tOFF)
GUID-9AFA5C5E-0138-4A50-A9F2-19798F6B6A6B-low.gif
CL includes probe and jig capacitance.
All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr < 5 ns, tf < 5 ns.
Figure 7-6 Break-Before-Make Time (tBBM)
GUID-58556066-2FC2-4446-99F2-FCF0EBAF6A09-low.gif Figure 7-7 Bandwidth (BW)
GUID-945C298A-959C-41C1-B291-ED821ADFFEC6-low.gif Figure 7-8 OFF Isolation (OISO)
GUID-4D2CEED7-1491-4B98-8A05-461F03AD952C-low.gif Figure 7-9 Crosstalk (XTALK)
GUID-10DCBC8D-AADB-457D-8318-2A4D941E865B-low.gif
All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr < 5 ns, tf < 5 ns.
CL includes probe and jig capacitance.
Figure 7-10 Charge Injection (QC)
GUID-FC021CD9-0FC8-4425-A151-245A1EE90172-low.gif
CL includes probe and jig capacitance.
Figure 7-11 Total Harmonic Distortion (THD)