6.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)(1)(2)
|
|
MIN |
MAX |
UNIT |
V+ |
Supply voltage(3) |
|
–0.5 |
4.6 |
V |
VS, VD |
Analog voltage(3)(4) |
–0.5 |
4.6 |
V |
ISK, IDK |
Analog port clamp current |
VS, VD < 0 |
–50 |
|
mA |
IS, ID |
ON-state switch current |
VS, VD = 0 to 7 V |
–128 |
128 |
mA |
VI |
Digital input voltage |
|
–0.5 |
4.6 |
V |
IIK |
Digital input clamp current(3)(4) |
VI < 0 |
–50 |
|
mA |
I+ |
Continuous current through V+ |
|
|
100 |
mA |
IGND |
Continuous current through GND |
|
–100 |
|
mA |
Tstg |
Storage temperature |
|
–65 |
150 |
°C |
(1) Stresses beyond those listed underAbsolute Maximum Ratings may cause permanent damage to thedevice. These are stress ratings only, and functional operation of the device at these or any otherconditions beyond those indicated under Recommended OperatingConditions is not implied. Exposure to absolute-maximum-rated conditions for extendedperiods may affect device reliability.
(2) The algebraic convention, whereby the most negative value is aminimum and the most positive value is a maximum.
(3) All voltages are with respect to ground, unless otherwisespecified.