over operating free-air temperature range (unless otherwise noted)(1)
|
|
MIN |
MAX |
UNIT |
VCCABSMAX
|
Supply voltage range |
–0.5 |
5.5 |
V |
VI/O-ABSMAX
|
Analog voltage range(2)
(3)
(4)
|
All I/O (data pins) |
–0.5 |
5.5 |
V |
VIN-ABSMAX
|
Digital input voltage range(2)
(3)
|
SEL1, SEL2, EN |
–0.5 |
5.5 |
V |
Tjmax
|
Maximum junction temperature |
–40 |
125 |
°C |
Tstg
|
Storage temperature range |
–65 |
150 |
°C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. Theseare stress ratings only, which do not imply functional operation of the device at these or anyother conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods mayaffect device reliability.
(2) All voltages are with respect to ground, unless otherwise specified.
(3) The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
(4) VI and VO are used to denote specific conditions for VI/O.