over operating free-air temperature range (unless otherwise noted)(1)
| MIN | MAX | UNIT |
---|
Supply voltage, VCC | –0.5 | 4.6 | V |
Control input voltage, VS, V OE (2) (3) | –0.5 | 7 | V |
Switch I/O voltage, VI/O (2) (3) (4) | –0.5 | 7 | V |
Control input clamp current, IIK | VIN < 0 | | –50 | mA |
I/O port clamp current, II/OK | VI/O < 0 | | –50 | mA |
ON-state switch current, II/O (5) | | ±120 | mA |
Continuous current through VCC or GND | | ±100 | mA |
Tstg | Storage temperature range | –65 | 150 | °C |
(1) Operation outside the Absolute Maximum Ratings may cause permanent
device damage. Absolute Maximum Ratings do not imply functional operation
of the device at these or any other conditions beyond those listed under
Recommended Operating Conditions. If used outside the Recommended
Operating Conditions but within the Absolute Maximum Ratings, the
device may not be fully functional, and this may affect device reliability,
functionality, performance, and shorten the device lifetime.
(2) All voltages are with respect to ground, unless otherwise specified.
(3) The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
(4) VI and VO are used to denote specific conditions for VI/O.
(5) II and IO are used to denote specific conditions for II/O.