ZHCSM72 June   2021 TUSB217A

PRODUCTION DATA  

  1. 特性
  2. 应用
  3. 说明
  4. Revision History
  5. Device Comparison
  6. Pin Configuration and Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 Switching Characteristics
    7. 7.7 Timing Requirements
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 High-Speed Boost
      2. 8.3.2 RX Sensitivity
    4. 8.4 Device Functional Modes
      1. 8.4.1 Low-Speed (LS) Mode
      2. 8.4.2 Full-Speed (FS) Mode
      3. 8.4.3 High-Speed (HS) Mode
      4. 8.4.4 High-Speed Downstream Port Electrical Compliance Test Mode
      5. 8.4.5 Shutdown Mode
      6. 8.4.6 I2C Mode
      7. 8.4.7 BC 1.2 Battery Charging Controller
    5. 8.5 TUSB217A Registers
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
        1. 9.2.2.1 Test Procedure to Construct USB High-speed Eye Diagram
          1. 9.2.2.1.1 For a Host Side Application
          2. 9.2.2.1.2 For a Device Side Application
      3. 9.2.3 Application Curves
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 接收文档更新通知
    2. 12.2 支持资源
    3. 12.3 Trademarks
    4. 12.4 Electrostatic Discharge Caution
    5. 12.5 术语表
  13. 13Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Absolute Maximum Ratings

Over operating free-air temperature range (unless otherwise noted) (1)
MIN MAX UNIT
Supply voltage range VCC –0.3 7 V
Voltage range USB data DxP, DxM –0.3 5.5 V
Voltage range on BOOST pin BOOST -0.3 1.98 V
Voltage range other pins RX_SEN, DCP/CDP,SDA,SCL, RSTN  -0.3 5.5 V
Storage temperature, Tstg –65 150 °C
Maximum junction temperature, TJ (max) 125 °C
Operation outside the Absolute Maximum Ratings may cause permanent device damage. Absolute Maximum Ratings do not imply functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If used outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device may not be fully functional, and this may affect device reliability, functionality, performance, and shorten the device lifetime.