ZHCSFQ2C November 2016 – June 2018 TUSB422
PRODUCTION DATA.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Reserved | FORCE_OFF_VBUS | VBUS_DIS_FAULT_DETECT_TIMER | VBUS_OCP_FAULT | VBUS_OVP_FAULT | Reserved | ||
R | R/W | R/W | R/W | R/W | R/W |
LEGEND: R/W = Read/Write; R = Read only |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7:5 | Reserved | R | 0 | Reserved |
4 | FORCE_OFF_VBUS | R/W | 0 | 0b: Allow STANDARD INPUT SIGNAL Force Off VBUS control (default)
1b: Block STANDARD INPUT SIGNAL Force Off VBUS control. This field has no meaning for TUSB422. |
3 | VBUS_DIS_FAULT_DETECT_TIMER | R/W | 0 | 0b: VBUS Discharge Fault Detection Timer enabled
1b: VBUS Discharge Fault Detection Timer disabled |
2 | VBUS_OCP_FAULT | R/W | 1 | 0b: Internal and External OCP circuit enabled
1b: Internal and External OCP circuit disabled This field has no meaning for TUSB422. |
1 | VBUS_OVP_FAULT | R/W | 1 | 0b: Internal and External OVP circuit enabled
1b: Internal and External OVP circuit disabled This field has no meaning for TUSB422. |
0 | Reserved | R/W | 0 | Reserved |