ZHCSHJ8C December   2017  – November 2019 TVS0500

PRODUCTION DATA.  

  1. 特性
  2. 应用
  3. 说明
    1.     Device Images
      1.      封装比较
      2.      对 8/20µs 浪涌事件的电压钳位响应
  4. 修订历史记录
  5. Device Comparison Table
  6. Pin Configuration and Functions
    1.     Pin Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings - JEDEC
    3. 7.3 ESD Ratings - IEC
    4. 7.4 Recommended Operating Conditions
    5. 7.5 Thermal Information
    6. 7.6 Electrical Characteristics
    7. 7.7 Typical Characteristics
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
    4. 8.4 Reliability Testing
    5. 8.5 Device Functional Modes
      1. 8.5.1 Protection Specifications
      2. 8.5.2 Minimal Derating
      3. 8.5.3 Transient Performance
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Configuration Options
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12器件和文档支持
    1. 12.1 接收文档更新通知
    2. 12.2 社区资源
    3. 12.3 商标
    4. 12.4 静电放电警告
    5. 12.5 Glossary
  13. 13机械、封装和可订购信息

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Absolute Maximum Ratings

TA = 27℃ (unless otherwise noted)(1)
MIN MAX UNIT
Maximum Surge IEC 61000-4-5 Current (8/20 µs) 43 A
IEC 61000-4-5 Power (8/20 µs) 400 W
IEC 61643-321 Current (10/1000 µs) 20 A
IEC 61643-321 Power (10/1000 µs) 180 W
Maximum Forward Surge IEC 61000-4-5 Current (8/20 µs) 50 A
IEC 61000-4-5 Power (8/20 µs) 80 W
IEC 61643-321 Current (10/1000 µs) 23 A
IEC 61643-321 Power (10/1000 µs) 60 W
EFT IEC 61000-4-4 EFT Protection 80 A
IBR DC Breakdown Current 50 mA
IF DC Forward Current 500 mA
TA Ambient Operating Temperature -40 125 °C
Tstg Storage Temperature -65 150 °C
Stresses beyond those listed under Absolute Maximum Rating may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Condition. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.